Measurement‑quality feedback for everyone who measures

Statistical quality assurance and structured QA reporting for fetal ultrasound and Doppler measurements, in hospitals, ultrasound practices, screening centres and research. Every measurement is compared with published reference charts, and every operator sees their own results.

EchoLab Reflect is a quality-assurance and feedback tool. It is not a medical device and is not intended for diagnosis or clinical decision-making.

Two views, one source of truth

The data that helps each operator grow is the same data that lets the organisation prove its quality is real.

For the person doing the work

In most skilled professions, you improve by following the data. You look at your performance, take honest feedback, and adjust. In fetal ultrasound that loop is rare, and where it exists it often arrives as a verdict from above. Reflect puts it back in your hands. Every operator gets a space of their own to see their results, follow their trends, and refine their technique on their own terms.

Your NT scans against the FMF reference

4050607080901.02.03.0CRL (mm)NT (mm)FMF medianP25–P75
4050607080901.02.03.0CRL (mm)NT (mm)FMF medianP25–P75

Example data for one operator. Every scan is placed against the published FMF reference; the band is the P25–P75 range.

For the organisation accountable for quality

When every operator can see and improve their own work, the practice can stand behind the result. Reflect turns personal quality assurance into organisational evidence: reproducible proof that a team’s measurements hold to a defined standard, audited against published references. A practice learns where to focus its coaching. A hospital or screening programme demonstrates the ongoing quality assurance that oversight bodies ask for.

NT bias per operator, with 95% confidence interval

OP-D512OP-L905OP-A4C1OP-G828OP-EF0COP-R773OP-F261OP-J144OP-K402OP-M118OP-C077OP-H215OP-N336OP-B390-0.6-0.3-0.10.0+0.1+0.3+0.6bias vs FMF expected NT (mm)
OP-D512OP-L905OP-A4C1OP-G828OP-EF0COP-R773OP-F261OP-J144OP-K402OP-M118OP-C077OP-H215OP-N336OP-B390-0.6-0.3-0.10.0+0.1+0.3+0.6bias vs FMF expected NT (mm)

Example data. Flag zones follow the app: within ±0.1 mm, check 0.1–0.3 mm, attention beyond 0.3 mm. Thresholds apply to the mean, never to a single scan.

Reflect works wherever fetal measurements are made: hospital departments, ultrasound practices, screening centres, midwifery practices, screening programmes and research groups.

Why measurement quality matters

Fetal biometry drives dating, growth assessment and the estimated fetal weight. The published evidence shows that small, systematic measurement errors are common, and that they change who is classified as small or large for gestational age. Quality assurance per operator is the agreed answer.

78%

of truly small fetuses detected when screening at the 10th percentile with typical measurement error, at a 4.7% false-positive rate. Halve the error spread and detection rises to 86.6% at 2.3%.

Wright, Wright, Smith & Nicolaides, UOG 2020 · founders’ work

2 mm

of crown–rump length error in the first trimester moves an estimated fetal weight on the 10th percentile to around the 5th or the 20th at the 20-week scan. Errors of 2 mm or more are common in practice.

Gadsbøll, Wright, Kristensen, Verfaille, Nicolaides, Wright & Petersen, UOG 2021

“Quality control in fetal biometry is essential for auditing and monitoring purposes.”

ISUOG Practice Guidelines: ultrasound assessment of fetal biometry and growth. Salomon LJ et al., UOG 2019

Selected publications

The papers behind Reflect’s approach. The platform’s 170+ reference charts come from 54 further publications, all listed on the publications page.

  • Impact of biometric measurement error on identification of small- and large-for-gestational-age fetuses

    Wright D, Wright A, Smith E, Nicolaides KH · Ultrasound Obstet Gynecol 2020;55:170–176

    doi.org/10.1002/uog.21909
    Founders
  • Crown–rump length measurement error: impact on assessment of growth

    Gadsbøll K, Wright A, Kristensen SE, Verfaille V, Nicolaides KH, Wright D, Petersen OB · Ultrasound Obstet Gynecol 2021;58:354–359

    doi.org/10.1002/uog.23690
    Founders
  • New charts for ultrasound dating of pregnancy and assessment of fetal growth: longitudinal data from a population-based cohort study

    Verburg BO, Steegers EAP, De Ridder M, Snijders RJM, Smith E, et al. · Ultrasound Obstet Gynecol 2008;31:388–396

    doi.org/10.1002/uog.5225
    Founders
  • ISUOG Practice Guidelines: ultrasound assessment of fetal biometry and growth

    Salomon LJ, Alfirevic Z, Da Silva Costa F, et al. · Ultrasound Obstet Gynecol 2019;53:715–723

    doi.org/10.1002/uog.20272
  • Intra- and interobserver variability in fetal ultrasound measurements

    Sarris I, Ioannou C, Chamberlain P, et al. · Ultrasound Obstet Gynecol 2012;39:266–273

    doi.org/10.1002/uog.10082
  • Quantitative approach to quality review of prenatal ultrasound examinations: fetal biometry

    Combs CA, Amara S, Kline C, Ashimi Balogun O, Bowman ZS · J Clin Med 2024;13:4860

    doi.org/10.3390/jcm13164860
  • AI to assist in the fetal anomaly ultrasound scan: a randomized controlled trial

    Day TG, Matthew J, Budd SF, Farruggia A, Venturini L, et al. · NEJM AI 2025;2(4)

    doi.org/10.1056/AIoa2400747
All publications and reference sources →

Everything your team needs

From data import to measurement-quality reports, one QA workflow for any team performing fetal ultrasound and biometry.

Operator reports and statistical analysis

Automatic comparison against validated reference charts. Mean z, percentile and a flag per measure for every operator, with scatter plots and bias metrics behind each row.

Mean z against your organisation’s charts

MeasureMean zPercentileReferenceFlag
Biparietal diameter−0.44 zP33−0.30 to +0.30Check
Head circumference−1.02 zP15−0.30 to +0.30Low
Abdominal circumference−0.10 zP46−0.30 to +0.30Within
Femur length+0.31 zP62−0.30 to +0.30Check
Crown–rump length+0.05 zP52−0.30 to +0.30Within

Within limits −0.30 to +0.30; check 0.30 to 0.50; needs attention 0.50 or more. Illustrative operator.

Organisation-wide overview

Figures and operator tables across your whole service. See who needs attention before problems compound, and show oversight bodies the ongoing quality assurance they ask for.

Operators
30
Measurements
3,973
Avg |z|
0.53
Reports
68
OperatorCountAvg |z|Status
OP-EF0C181.21
Attention
OP-7D59731.11
Attention
OP-51A84470.77
Check
OP-3299590.22
Within
OP-A4C12120.31
Check

Illustrative organisation · a different sample from the report above

Data import, from file or from the scanner

Upload CSV, XLS or XLSX files with automatic column mapping, or connect the DICOM gateway so measurements arrive from the ultrasound system as they are made.

1Upload2Map columns3Operators4Confirm
CSV columnReflect field
operator_id→Operator IDauto
scan_date→Scan dateauto
ga_weeks→Gestational age (weeks)auto
bpd→BPDauto
hc→HCauto
ac→ACauto
fl→FLauto

Also DICOM SR through the Reflect gateway, per site.

Choose from 170+ reference charts, or add your own

Published charts for fetal biometry and NT from 54 peer-reviewed sources: Verburg, Robinson & Fleming, INTERGROWTH-21st, Hadlock, the FMF sets and more. Choose the charts your organisation works with, per measurement, or add your own local charts.

All reference sources →

Verburg 2008 · Netherlands · 4 charts · default

P95P50P5152025303540Gestational age (weeks)
ACAbdominal circumference (mm)10.0 – 42.0 wks
BPDBiparietal diameter (mm)10.0 – 42.0 wks
FLFemur length (mm)12.0 – 42.0 wks
HCHead circumference (mm)10.0 – 42.0 wks

Coming soon

Two additions to Reflect in development, built with the same per-operator comparison against published references.

In development

Doppler quality assurance

Quality assurance for Doppler measurements: pulsatility and resistance indices of the umbilical, middle cerebral and uterine arteries, and the ductus venosus. Each operator’s values are compared with published reference curves, in the same reports as biometry and NT.

Umbilical artery PI · Ciobanu 2019 (FMF) · 20–42 weeks

P95P50P50.61.01.4222630343842Gestational age (weeks)
UA-PIUmbilical artery pulsatility index20–42 wks
MCA-PIMiddle cerebral artery pulsatility index20–42 wks
CPRCerebroplacental ratio20–42 wks

Reference curves already in Reflect: the FMF ranges of Ciobanu et al. 2019, drawn here from the published formulas. Further curves for the uterine arteries and the ductus venosus follow.

Coming soon

Reflect on your phone and tablet

Your own results and trends on the device you carry: open your latest report, follow your measurements over time and see where to focus, wherever you are.

The Reflect app opening on a phone
An operator's own report on a phone: each measure's percentile position against the reference

Preview of the phone view, with example data.

From data to measurement-quality feedback

A three-step workflow that fits the way a department already works.

1

Connect and import

Upload measurement data as CSV, XLS or XLSX, or let the DICOM gateway collect it from the scanner. Automatic column mapping recognises standard fetal biometry fields.

2

Automatic analysis

Reflect compares every measurement with validated reference charts and flags the operators and measurements that need a second look.

3

Reports and feedback

Structured operator and organisation reports. Export as PDF, or share within the platform so each operator sees their own results.

Built by clinicians, statisticians and engineers

Reflect is built by a team that has worked in prenatal screening, biometry quality assurance and digital product design for over twenty years.

David Wright

Co-founder · Statistics & QA

Professor of Medical Statistics at the University of Exeter. Lead statistician for the Down’s syndrome screening QA service (DQASS) since 2006, statistician for the ASPRE trial, and member of the NHS Fetal Anomaly Screening Programme for over ten years.

Alan Wright

Co-founder · Statistics & software

Statistician and honorary Research Fellow at the University of Exeter, working with the Fetal Medicine Foundation group. Builds the software behind external statistical evaluation reports for QA of biochemical and biophysical data.

Eric Smith

Co-founder · Prenatal screening & fetal ultrasound

Founded and led a regional prenatal screening centre in the Netherlands for twenty years, combining clinical ultrasound with running the practice. Publications span first-trimester screening, fetal growth charts, Doppler reliability and AI model evaluation.

Beer Buijsman

Co-founder · Service & platform design

Runs De Oplosser, a Rotterdam product and service design studio. Twenty years of digital product work for bol.com, IKEA, Booking.com and Polestar.

Request a demo

See Reflect in action. We’ll walk you through the platform and show how it fits the way your team works.

Location
The Netherlands