Measurement‑quality feedback for everyone who measures
Statistical quality assurance and structured QA reporting for fetal ultrasound and Doppler measurements, in hospitals, ultrasound practices, screening centres and research. Every measurement is compared with published reference charts, and every operator sees their own results.
EchoLab Reflect is a quality-assurance and feedback tool. It is not a medical device and is not intended for diagnosis or clinical decision-making.
Two views, one source of truth
The data that helps each operator grow is the same data that lets the organisation prove its quality is real.
For the person doing the work
In most skilled professions, you improve by following the data. You look at your performance, take honest feedback, and adjust. In fetal ultrasound that loop is rare, and where it exists it often arrives as a verdict from above. Reflect puts it back in your hands. Every operator gets a space of their own to see their results, follow their trends, and refine their technique on their own terms.
Your NT scans against the FMF reference
Example data for one operator. Every scan is placed against the published FMF reference; the band is the P25–P75 range.
For the organisation accountable for quality
When every operator can see and improve their own work, the practice can stand behind the result. Reflect turns personal quality assurance into organisational evidence: reproducible proof that a team’s measurements hold to a defined standard, audited against published references. A practice learns where to focus its coaching. A hospital or screening programme demonstrates the ongoing quality assurance that oversight bodies ask for.
NT bias per operator, with 95% confidence interval
Example data. Flag zones follow the app: within ±0.1 mm, check 0.1–0.3 mm, attention beyond 0.3 mm. Thresholds apply to the mean, never to a single scan.
Reflect works wherever fetal measurements are made: hospital departments, ultrasound practices, screening centres, midwifery practices, screening programmes and research groups.
Why measurement quality matters
Fetal biometry drives dating, growth assessment and the estimated fetal weight. The published evidence shows that small, systematic measurement errors are common, and that they change who is classified as small or large for gestational age. Quality assurance per operator is the agreed answer.
78%
of truly small fetuses detected when screening at the 10th percentile with typical measurement error, at a 4.7% false-positive rate. Halve the error spread and detection rises to 86.6% at 2.3%.
Wright, Wright, Smith & Nicolaides, UOG 2020 · founders’ work
2 mm
of crown–rump length error in the first trimester moves an estimated fetal weight on the 10th percentile to around the 5th or the 20th at the 20-week scan. Errors of 2 mm or more are common in practice.
From data import to measurement-quality reports, one QA workflow for any team performing fetal ultrasound and biometry.
Operator reports and statistical analysis
Automatic comparison against validated reference charts. Mean z, percentile and a flag per measure for every operator, with scatter plots and bias metrics behind each row.
Mean z against your organisation’s charts
Measure
Mean z
Percentile
Reference
Flag
Biparietal diameter
−0.44 z
P33
−0.30 to +0.30
Check
Head circumference
−1.02 z
P15
−0.30 to +0.30
Low
Abdominal circumference
−0.10 z
P46
−0.30 to +0.30
Within
Femur length
+0.31 z
P62
−0.30 to +0.30
Check
Crown–rump length
+0.05 z
P52
−0.30 to +0.30
Within
Within limits −0.30 to +0.30; check 0.30 to 0.50; needs attention 0.50 or more. Illustrative operator.
Organisation-wide overview
Figures and operator tables across your whole service. See who needs attention before problems compound, and show oversight bodies the ongoing quality assurance they ask for.
Operators
30
Measurements
3,973
Avg |z|
0.53
Reports
68
Operator
Count
Avg |z|
Status
OP-EF0C
18
1.21
Attention
OP-7D59
73
1.11
Attention
OP-51A8
447
0.77
Check
OP-3299
59
0.22
Within
OP-A4C1
212
0.31
Check
Illustrative organisation · a different sample from the report above
Data import, from file or from the scanner
Upload CSV, XLS or XLSX files with automatic column mapping, or connect the DICOM gateway so measurements arrive from the ultrasound system as they are made.
1Upload2Map columns3Operators4Confirm
CSV column
Reflect field
operator_id
→
Operator ID
auto
scan_date
→
Scan date
auto
ga_weeks
→
Gestational age (weeks)
auto
bpd
→
BPD
auto
hc
→
HC
auto
ac
→
AC
auto
fl
→
FL
auto
Also DICOM SR through the Reflect gateway, per site.
Choose from 170+ reference charts, or add your own
Published charts for fetal biometry and NT from 54 peer-reviewed sources: Verburg, Robinson & Fleming, INTERGROWTH-21st, Hadlock, the FMF sets and more. Choose the charts your organisation works with, per measurement, or add your own local charts.
Two additions to Reflect in development, built with the same per-operator comparison against published references.
In development
Doppler quality assurance
Quality assurance for Doppler measurements: pulsatility and resistance indices of the umbilical, middle cerebral and uterine arteries, and the ductus venosus. Each operator’s values are compared with published reference curves, in the same reports as biometry and NT.
Umbilical artery PI · Ciobanu 2019 (FMF) · 20–42 weeks
UA-PI
Umbilical artery pulsatility index
20–42 wks
MCA-PI
Middle cerebral artery pulsatility index
20–42 wks
CPR
Cerebroplacental ratio
20–42 wks
Reference curves already in Reflect: the FMF ranges of Ciobanu et al. 2019, drawn here from the published formulas. Further curves for the uterine arteries and the ductus venosus follow.
Coming soon
Reflect on your phone and tablet
Your own results and trends on the device you carry: open your latest report, follow your measurements over time and see where to focus, wherever you are.
Preview of the phone view, with example data.
From data to measurement-quality feedback
A three-step workflow that fits the way a department already works.
1
Connect and import
Upload measurement data as CSV, XLS or XLSX, or let the DICOM gateway collect it from the scanner. Automatic column mapping recognises standard fetal biometry fields.
2
Automatic analysis
Reflect compares every measurement with validated reference charts and flags the operators and measurements that need a second look.
3
Reports and feedback
Structured operator and organisation reports. Export as PDF, or share within the platform so each operator sees their own results.
Built by clinicians, statisticians and engineers
Reflect is built by a team that has worked in prenatal screening, biometry quality assurance and digital product design for over twenty years.
DW
David Wright
Co-founder · Statistics & QA
Professor of Medical Statistics at the University of Exeter. Lead statistician for the Down’s syndrome screening QA service (DQASS) since 2006, statistician for the ASPRE trial, and member of the NHS Fetal Anomaly Screening Programme for over ten years.
AW
Alan Wright
Co-founder · Statistics & software
Statistician and honorary Research Fellow at the University of Exeter, working with the Fetal Medicine Foundation group. Builds the software behind external statistical evaluation reports for QA of biochemical and biophysical data.
Founded and led a regional prenatal screening centre in the Netherlands for twenty years, combining clinical ultrasound with running the practice. Publications span first-trimester screening, fetal growth charts, Doppler reliability and AI model evaluation.
BB
Beer Buijsman
Co-founder · Service & platform design
Runs De Oplosser, a Rotterdam product and service design studio. Twenty years of digital product work for bol.com, IKEA, Booking.com and Polestar.
Request a demo
See Reflect in action. We’ll walk you through the platform and show how it fits the way your team works.