STAGING ENVIRONMENT - Changes here do not affect production

Publications and reference sources

The evidence Reflect is built on: the papers behind its approach to measurement quality, and the published sources of every reference chart in the platform.

Selected publications

Peer-reviewed work on measurement error, quality control and reference charts in fetal ultrasound. Papers marked Founders were co-authored by the Reflect team.

  • Impact of biometric measurement error on identification of small- and large-for-gestational-age fetuses

    Wright D, Wright A, Smith E, Nicolaides KH · Ultrasound Obstet Gynecol 2020;55:170–176

    doi.org/10.1002/uog.21909
    Founders
  • Crown–rump length measurement error: impact on assessment of growth

    Gadsbøll K, Wright A, Kristensen SE, Verfaille V, Nicolaides KH, Wright D, Petersen OB · Ultrasound Obstet Gynecol 2021;58:354–359

    doi.org/10.1002/uog.23690
    Founders
  • New charts for ultrasound dating of pregnancy and assessment of fetal growth: longitudinal data from a population-based cohort study

    Verburg BO, Steegers EAP, De Ridder M, Snijders RJM, Smith E, et al. · Ultrasound Obstet Gynecol 2008;31:388–396

    doi.org/10.1002/uog.5225
    Founders
  • ISUOG Practice Guidelines: ultrasound assessment of fetal biometry and growth

    Salomon LJ, Alfirevic Z, Da Silva Costa F, et al. · Ultrasound Obstet Gynecol 2019;53:715–723

    doi.org/10.1002/uog.20272
  • Intra- and interobserver variability in fetal ultrasound measurements

    Sarris I, Ioannou C, Chamberlain P, et al. · Ultrasound Obstet Gynecol 2012;39:266–273

    doi.org/10.1002/uog.10082
  • Quantitative approach to quality review of prenatal ultrasound examinations: fetal biometry

    Combs CA, Amara S, Kline C, Ashimi Balogun O, Bowman ZS · J Clin Med 2024;13:4860

    doi.org/10.3390/jcm13164860
  • AI to assist in the fetal anomaly ultrasound scan: a randomized controlled trial

    Day TG, Matthew J, Budd SF, Farruggia A, Venturini L, et al. · NEJM AI 2025;2(4)

    doi.org/10.1056/AIoa2400747

Reference chart sources

Reflect compares every measurement with charts from these 54 publications: 178 charts in total, covering fetal biometry and estimated fetal weight across populations and regions. Nuchal translucency is assessed against the Fetal Medicine Foundation model. Your organisation chooses which charts to use per measurement, and can add its own.

Chart counts as in the platform on 16 November 2026.

PublicationCharts
Acharya et al. SAFOG 2009; 1: 55-614
Brenner et al. Am J Obstet Gynecol 1976; 126: 555-5641
Buck Louis et al. Am J Obstet Gynecol 2015; 213: 449.e1-449.e416
Chavez et al. Am J Obstet Gynecol 2003; 189: 1021-10251
Chitty et al. BJOG 1994; 101: 35-435
Chitty et al. BJOG 1994; 101: 125-1312
Chitty et al. BJOG 1994; 101: 132-1351
Chitty et al. BJOG 2002; 109: 919-9297
Créquat et al. Gynecol Obstet Fertil 2000; 28: 435-445Biométrie 20004
Figueras et al. Eur J Obstet Gynecol Reprod Biol 2008; 136: 20-242
Gjessing et al. Ultrasound Obstet Gynecol 2017; 49: 500-507eSnurra2
Gonzalez et al. Rev Méd Chile 2004; 132: 1155-11651
Hadlock et al. J Ultrasound Med 1982; 151: 97-1041
Hadlock et al. Radiology 1984; 152: 497-5014
Hadlock et al. Radiology 1991; 181: 129-1331
Harris Birthright Research Centre for Fetal Medicine, King’s College Hospital, London, UK 19951
Jeanty et al. Am J Perinatol 1984; 1: 136-1442
Johnsen et al. Eur J Obstet Gynecol Reprod Biol 2006; 127: 172-1854
Johnsen et al. Acta Obstet Gynecol Scand 2006; 85: 286-2971
Kiserud et al. PLoS Med 2017; 14: e1002220WHO charts6
Kramer et al. Pediatrics 2001; 108: e351
Kuhn et al. Am J Obstet Gynecol 1995; 172: 32-351
Kurmanavicius et al. Br J Obstet Gynaecol 1999; 106: 126-1435
Kustermann et al. BJOG 1992; 99: 38-425
Lai et al. Singapore Med J 1995; 36: 628-6365
Leung et al. Ultrasound Obstet Gynecol 2008; 31: 321-3275
Loughna et al. Ultrasound 2009; 17: 161-1671
Marsal et al. Acta Paediatr 1996; 85: 843-8482
Merz et al. Ultraschall Med 1996; 17: 153-16210
Merz et al. Ultraschall Med 2023; 44: 179-18710
Munim et al. J Matern Fetal Neonatal Med 2011; online: 1-74
Nicolaides et al. Ultrasound Obstet Gynecol 2018; 52: 44-511
Nicolini et al. Minerva Ginecol 1986; 38: 873-8873
Papageorghiou et al. Lancet 2014; 384: 869-879INTERGROWTH-21st5
Papageorghiou et al. Ultrasound Obstet Gynecol 2014; 44: 641-648INTERGROWTH-21st1
Papaioannou et al. Fetal Diagn Ther 2010; 28: 207-2191
Persson et al. Acta Obstet Gynecol Scand 1986; 65: 759-7613
Pexters et al. Ultrasound Obstet Gynecol 2010; 35: 650-6551
Robinson HP, Fleming JEE. Br J Obstet Gynaecol 1975; 82: 702-7103
Romero et al. Appleton and Lange 1988: 318-3255
Salomon et al. Ultrasound Obstet Gynecol 2003; 22: 63-663
Salomon et al. Ultrasound Obstet Gynecol 2006; 28: 193-1984
Salomon et al. Ultrasound Obstet Gynecol 2007; 29: 550-5551
Sherer et al. Ultrasound Obstet Gynecol 2007; 29: 32-371
Snijders et al. Ultrasound Obstet Gynecol 1994; 4: 34-486
Sotiriadis et al. Eur J Clin Invest 2016; 46: 425-4335
Sotiriadis et al. J Matern Fetal Neonatal Med 2018; 31: 761-7691
Souka et al. J Matern Fetal Neonatal Med 2014; 27: 737-7421
Stirnemann et al. Ultrasound Obstet Gynecol 2020; 56: 946-948INTERGROWTH-21st1
Stirrup et al. Ultrasound Obstet Gynecol 2015; 45: 301-307STORK8
Verburg et al. Ultrasound Obstet Gynecol 2008; 31: 388-3969
Westerway et al. Aust N Z J Obstet Gynaecol 2000; 40: 297-3026
Williams et al. Obstet Gynecol 1982; 59: 624-6321
Yudkin et al. Early Hum Dev 1987; 15: 45-523